Question About 'Square d 150 kva transformer'

What is the maximum flux density of a 250 kVA transformer?

The maximum flux density in the core of a 250/3000 V, 50 Hz, 1-Φ transformer is 1.2 Wb/m2.If the emf/turn is 8 V, determine the primary & secondary turns. A 25-kVA transformer has 500 turns on the primary & 100 turns on the secondary winding.

http://sk4education.com/engineering/Question/8245.doc


What is the efficiency of a 400 kVA single phase transformer?

The efficiency of a 400 kVA, single – phase transformer is 98.77% when delivering full – load at 0.8 p.f. lagging and 99.13% at half full – load at unity p.f. Calculate (i) Iron loss and (ii) Full – load copper loss. UNIT-III INDUCTION MOTORS PART-A

http://sk4education.com/engineering/Question/8245.doc


What is the required voltage ratio in a 150kva 50 Hz transformer?

The required N.L voltage ratio in a 150kVA, 50 Hz 1-Φ transformer is 5000 / 250V. Find the number of turns in each winding for a maximum core flux of 0.06 Wb & efficiency at half rated KVA, u.p.f.

http://sk4education.com/engineering/Question/8245.doc


What is the secondary voltage of a 1-φ transformer?

The voltage/turn of a 1-Φ transformer is 1.1V, when the primary winding is connected to a 220V, 50Hz ac supply, the secondary voltage is found to be 660V.Find (1) Primary & secondary currents (2) the core area if the maximum flux density is 1.2 T.

http://sk4education.com/engineering/Question/8245.doc


doc for "square d 150 kva transformer".(Page 1 of about 16 results)

"square d 150 kva transformer"


doc ico  Low voltage transformers - Fontana Unified School District

Transformers shall be self-cooled type with 220 degrees C. insulation and a maximum temperature rise of 150 degrees C. under continuous full load conditions with an ambient of 40 …

doc ico  JustAnswer

The plant load is 400 kVA. Compare the transformer losses when single transformer is operation and when both transformers are in parallel operation. losses when single transformer is …

doc ico  United Nations Development Programme

The material shall be subjected to. inspection and test by our inspectors or international inspector any time during manufacture

doc ico  IEEE Standards - draft standard template

Table 10-10—Liquid-immersed and dry-type transformer standard base kVA ratings. ... For instance, a 115 °C transformer has a life expectancy about ten times greater than that of a 150 …

doc ico  AC 150/5345-10G, Specification For Constant Current …

CCR oil immersed transformer enclosures must allow no seepage of oil from welds, gaskets, seals, or vents. Oil immersed transformer enclosures must be equipped with a sampling/drain …

doc ico  PSG Section 16461 - Eaton

Transformer ratings including: kVA. Primary and secondary voltage. Taps. Design impedance. Insulation class and temperature rise. Sound level. ... 0 to 9 kVA 40 dB 10 to 50 kVA 45 dB 51 …

doc ico  PSG Section 16461 - Eaton

Transformer must bear the UL Energy Efficiency Verification Mark to confirm that the unit meets the requirements of 10 CFR Part 431. ... 5-45 kVA minimum of 200 degrees C insulation system with [80] [115] [130] [150] degree C rise; 50 kVA and above: minimum of 220 degrees C insulation system with [80] [130] [115] [150] degree C rise, ventilated ...

doc ico  PRODUCT SPECIFICATION FOR A 15 TO 500 KVA, - Online …

The transformer shall be designed for a maximum temperature rise of 150° C above 40° C ambient, as measured. by the rise change or resistance method. The maximum temperature …

doc ico  1 .

The daily variation of load on a 100 KVA transformer is as follows: 8:00 AM to 1:00 PM ----- 65 KW,45 KVAR 1:00 PM to 6:00 PM ----- 80 KW,50 KVAR ... Determine the all-day efficiency of the …

doc ico  SECTION 16326000 - ABB

The average temperature rise of the transformer windings shall be rated at (80°C, 115°C, 150°C) and shall be built utilizing Class 220°C insulations, regardless of the temperature rise specified. …

doc ico  Www.etenders.gov.za

KVA : TRANSFORMER: S AND MINI SUBS: OF VARIOUS SIZES: A: T ESKOM : SITE: S: IN GAUTENG: JOHANNESBURG ZONE: FOR : 12: MONTHS: CONTRACT: ENQUIRY NUMBER: MWP …

doc ico  QUESTION BANK - Department of ECE

The maximum efficiency of 50 KVA transformer is 97.4% and occurs at 90% of the full-load. Calculate the efficiency of transformer at ... square of supply voltage D) all of the above. 17. …

doc ico  Medium Voltage Metal-Clad Switchgear Specification - ABB

The circuit breaker door must be provided with impact resistant lexan viewing window of at least 86 square inches and ½” thick to determine breaker position, open/closed indicator, spring …

doc ico  UNIT – I

A 5-kVA transformer has iron loss & copper loss of 100 & 200W respectively. Determine the efficiency at half F.L & 0.8 power factor lagging. The efficiency of a 400 kVA, single – phase …

doc ico  SECTION 261213 - LIQUID-FILLED MEDIUM-VOLTAGE …

Square D. LIQUID-FILLED POWER TRANSFORMERS. Liquid-filled Transformers: ANSI C57.12.00; three-phase, self-cooled transformer unit. Capacity: [_____] kVA. Primary Voltage: 12.47 kV, …

doc ico  SECTION 262313 - PARALLELING LOW-VOLTAGE SWITCHGEAR

Control Power Supply: Control power transformer supplies 120-V control circuits through secondary disconnect devices. Include the following features: Dry-type transformers, in …